47 mm Microfiltration Assembly, Fritted Glass Support with Silicone Stopper ( without filtering Fask )
FAVORIT® 47 mm vacuum microfiltration assembly handles up to 500 mL of liquid samples,
separating particles through a fine filter under vacuum pressure, crucial for removing microbiological contamination in laboratory processes.
They are also highly chemical resistant making them suitable for all common laboratory
applications.
• Supplied with a 40-60 micron porosity fritted glass support base, a 300 mL graduated funnel, an anodized aluminum clamp and a silicone stopper.
• Funnels are graduated from 100 to 250 mL in 25 mL increments.
• Prefilter size is 35 mm.
• Approximate filter area is 9.6 cm ².
• Connection to 1000mL filtration Flask (available as an accessory) is made with a No.16 silicone stopper.
47 mm Microfiltration Assembly with Fritted Glass Support
and Ground Joint
A
47 mm filtration apparatus with fritted glass support is commonly used in laboratory settings
for separating solids from liquids or gases. It's widely utilized in various filtration and
purification processes, and recommended for routine filtration analysis of corrosive liquids and
the removal of particulates from HPLC solvent.
• Ground joint connection prevents the possibility of phthalate contamination, which may arise
when engaging with silicone or neoprene stoppers.
• The support base features a glass frit with a porosity of 40-60 microns and an integrated
vacuum connection positioned above the drip tip, preventing the vacuum line from being
contaminated by filtrate droplets.
• Each apparatus is supplied with a funnel, an anodized aluminum clamp, a 47 mm fritted glass
support base and a filtration Flask.
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I
and ASTM E438, Type I, Class A requirements.
47mm Microfiltration Assembly, with PTFE Insert and Clamp
For optimal Flow rate when filtering viscous or proteinaceous solutions, it's recommended to
utilize the 47mm Filtration Apparatus With Stainless Steel Support.
• This apparatus is also used to produce ultra-clean filtrate since the stainless steel screen
will not shed particles into the filtrate.
• Ground joint connection prevents the possibility of phthalate contamination, which may
arise when engaging with silicone or neoprene stoppers.
• Each apparatus is supplied with a funnel, an anodized aluminum clamp, a stainless steel
support screen, a PTFE gasket, a 47 mm glass support base and a filtration Flask.
• 80 x 80 304 stainless steel mesh, 0.0055" opening size, 19.4% open area, 0.007" wire
diameter.
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP
Type I and ASTM E438, Type I, Class A requirements.
47 mm Microfiltration Assembly with Solvent Pick-Up Adapter
and Ground Joint
This all glass microfiltration system eliminates pouring HPLC solvents into funnels.
• The solvent pickup adapter draws solvent directly from a reagent bottle through a 47 mm
filter and into a filter Flask
• After filtration is complete, valve on the solvent pickup adapter can be turned off for
vacuum degassing.
• Existing filtration assemblies are easily converted to in-line filtration/degassing by
replacing existing funnels with solvent pickup adapters. They clamp to support bases in the
same way that funnels do.
• This system comes with a solvent pickup adapter, a coarse porosity fritted glass filter base,
an inner joint flask and an aluminum clamp.
• The support base has a 40-60 micron porosity glass frit and an integral vacuum connection
above the drip tip to prevent contamination of the vacuum line with filtrate droplets.
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP
Type I and ASTM E438, Type I, Class A requirements.
47 mm Microfiltration Assembly With Thread Connection
and Standard Pick up Adapter
Microfiltration system skip the hassle of pouring HPLC solvents into funnels.
• The solvent pickup adapter draws solvent directly from a reagent bottle through a 47 mm
filter and into a filter flask
• After filtration is complete, valve on the solvent pickup adapter can be turned off for
vacuum degassing.
• Existing filtration assemblies are easily converted to in-line filtration/degassing by
replacing existing funnels with solvent pickup adapters. They clamp to support bases in the
same way that funnels do.
• This system comes with a solvent pickup adapter, a coarse porosity fritted glass filter base,
GL45 Thread Connection Flask and an aluminum clamp.
• The support base has a 40-60 micron porosity glass frit and an integral vacuum connection
above the drip tip to prevent contamination of the vacuum line with filtrate droplets.
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP
Type I and ASTM E438, Type I, Class A requirements.
25 mm, Microfiltration Assembly with Fritted Glass Support
The 25 mm vacuum microfiltration assembly is designed to handle small volumes of
liquids for analysis of particulate or microbiological contamination. It has a fritted glass
support and is used for general filtration.
• Supplied with a 40-60 micron porosity fritted glass support base, a 15 mL graduated
funnel, an anodized aluminum clamp and a Silicone stopper.
• Funnels are graduated from 5 to 15 mL in 1 mL increments.
• Prefilter size is 16 mm diameter.
• Approximate filter area is 2.5 cm ².
• Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP
Type I and ASTM E438, Type I, Class A requirements.
DOWNLOAD BROCCURE
For more information and purchases please contact us:
Whatsapp: 081221661208
Email: moellyana.amoebabio@gmail.com